Cardiac Rehab

Category: 
Supplier: 

Requirements in cardiology and cardiac rehabilitation
Cardiac rehabilitation
Cardiac rehabilitation is the coordinated sum total of measures, which are necessary to create the best possible physical, psychological and social circumstances, for a patient with chronical or cardio-vascular illness following a recent acute incident, to be able to return to or keep their accustomed place in society out of their own power, and to restrict or to turn back the progress of the disease through improved life habits - WHO 1993.

Requirements for the equipment
A comfortable training monitoring for the therapist and an easy access to all relevant data during the training is necessary. Also an immediate training influence (load, training pulse) on the patient.
Phase I:
Early mobilisation - after the acute event in the hospital

Phase II:
Following the treatment in the hospital - preferably in-patient treatment in a rehab clinic - duration approx. 4 weeks

Phase III:
Out-patient rehabilitation in an outpatient rehab institution - duration generally 1 year

Phase IV:
Heart groups - duration lifetime - 1 - 2x / Week

Different training forms must be supported:
Heart rate controlled, the training pulse of the patient has to be kept stable through automatic load control and load control with predefined load profiles as well as manual training.
A ccontinuous ECG-recording with monitoring of heart rate, arrhythmias, oxygen lows, blood pressure is necessary as well as a data base for full documentation. The alarm has to be defined according to patient training duration and to be set for each single patient or the whole group.

A complete registration and documentation of all important cardio-vascular parameters and the
connection with a hospital or surgery data base,network compatible, must be ensured.

product description
Running machine h/p/cosmos mercury med
Running surface 150 x 50 cm, Speed 0 ... 22 km/h, Elevation 0 ... 25 %, Drive motor 3.3 kW
Interface port com1 for PC, ECG, Ergo spirometry-, Blood-pressure system or printer - compatible to most of the systems worldwide, , incl. PC software h/p/cosmos para control for device control and monitoring
Handrail long, 2 pillars (surcharge)

Reverse belt rotation for downhill simulation

h/p/cosmos arm support, adjustable in height and width

h/p/cosmos additional keyboard for arm support and for remote control, 6 keys, 2 m cable

h/p/cosmos additional stop-button for arm support, right hand
2nd interface port com2 for PC, ECG, Ergo spirometry-, Blood-pressure system or printer
Interface cable RS232, 5 m
h/p/cosmos satellite print - printer-Set for direct documentation without PC, incl. laser printer, RS232 converter with cable, printer rack
Potential equalization cable, 5 m (required for medical systems)